For the quantitative in vitro determination of Procine CXC-chemokine ligand 14 concentrations in
serum - plasma - tissue homogenates - other biological fluids
FOR LABORATORY RESEARCH USE ONLY.
NOT FOR USE IN DIAGNOSTIC PROCEDURES.
This package insert must be read in its entirety before using thisproduct.
ELISA
ENZYME LINKED IMMUNOSORBENT ASSAY
INTENDEDUSE AND TEST PRINCIPLE
This CXCL14ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of CXCL14in the sample, this CXCL14ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus CXCL14concentration. The concentration of CXCL14in the samples is then determined by comparing the O.D. of the samples to the standard curve.
SAMPLE COLLECTION AND STORAGES
Serum - Use a serum separator tube and allow samples to clot for two hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximately 1000×g. Assay freshly prepared serumimmediately or store samples in aliquot at -20℃ or -80℃ for later use. Avoid repeated freeze/thaw cycles.
Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at1000×g at 2-8℃ within 30 minutes of collection. Remove plasma and assay immediately or store samplesin aliquot at -20℃ or -80℃ for later use. Avoid repeated freeze/thaw cycles.
Tissue homogenates - For general information, hemolysis blood may affect the result, so you shouldrinse the tissues with ice-cold PBS (0.01M, pH=7.4) to remove excess blood thoroughly. Tissuepieces should be weighed and then minced to small pieces which will be homogenized in PBS (thevolume depends on the weight of the tissue. 9mL PBS would be appropriate to 1 gram tissue pieces.Some protease inhibitor is recommended to add into the PBS.) with a glass homogenizer on ice. Tofurther break the cells, you can sonicate the suspension with an ultrasonic cell disrupter or subject it tofreeze-thaw cycles. The homogenates are then centrifugated for 5minutes at 5000×g to get thesupernate.
Cell culture supernatesand other biological fluids -Centrifuge samples for 20 minutes at 1000×g. Removeparticulates and assay immediately or store samples in aliquot at -20℃ or -80℃ for later use. Avoid repeatedfreeze/thaw cycles.
Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.
MATERIALSREQUIREDBUTNOT SUPPLIED
1. 37 ℃ incubator
2. Standard microplate readercapableof measuringabsorbanceat450nm
3. Precision pipettes, disposable pipette tips and Absorbent paper
4. Distilled or deionized water
REAGENTS PROVIDED
All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.
Name
96determinations
48 determinations
MICROTITERPLATE
8*12strips
8*6strips
STANDARD(6 vial)
0.3ml/vial
0.3ml/vial
SAMPLE DILUENT
6.0ml
3.0ml
ENZYME CONJUGATE
10.0ml
5.0ml
WASH SOLUTION
25ml
15ml
SUBSTRATE A
6.0ml
3.0ml
SUBSTRATE B
6.0ml
3.0ml
STOP SOLUTION
6.0ml
3.0ml
Closure plate membrane
2
2
User manual
1
1
Sealed bags
1
1
Note:
1. Standard concentrationwas followed by: , 0, 0, 0, 0, 0 .
2. If samples generate values higher than the highest standard, please dilute thesamples with Sample Diluent and repeat the assay.
PRECAUTIONS
Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
Do not use kit components beyond their expiration date.
Use only deionized or distilled water to dilute reagents.
Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
Use fresh disposable pipette tips for each transfer to avoid contamination.
Do not mix acid and sodium hypochlorite solutions.
Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
All samples should be disposed of in a manner that will inactivate viruses.
Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
Substrate Solution is easily contaminated. If bluish prior to use, do not use.
Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).
REAGENT PREPARATION AND STORAGE
Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.
ASSAY PROCEDURE
1. Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microtiter plate.
2. Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.
3. Add100μlofEnzymeconjugate to standard wells and sample wells except the blank well, cover with an adhesive stripandincubatefor60 minutes at37°C.
4. Wash the Microtiter Plate 4 times.
Manual Washing- Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of fourtimes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.
Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.
5. Add Substrate A 50μl and Substrate B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.
6. Add 50μl Stop Solution to each well. The color in the wells should change from blue toyellow. If the color in the wells is green or the color change does notappear uniform,gently tap the plate to ensure thorough mixing.
This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.
First, calculate the mean O.D. value for each standard and sample. All O.D. Valuesare subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.
To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
Intra-assay CV(%) is less than 10% and Inter-assay CV(%) is less than 15%.
Assay range: 0 – .
7. Sensitivity: The minimum detectable dose of ProcineCXCL14 is typically less than 10 .
8. Cross-reactivity: This assay recognizes recombinant and natural ProcineCXCL14. No significantcross-reactivity or interference was observed.
9. Storage: 2-8℃ (Use frequently); six months (-20℃)。
10.Standard curve
FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS!PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!
豬CXC趨化因子配體14(CXCL14)試劑盒(ELISA)
使用說(shuō)明書(shū)
l 本試劑盒用于體外定量檢測(cè)血清、血漿、組織勻漿及相關(guān)液體樣本中豬CXC趨化因子配體14(CXCL14)的含量。