激情综合啪啪6月丁香,久久久久国产精品91福利,99精品日韩欧美在线观看,91成人午夜福利在线观看国产

上海逸峰生物科技有限公司

當前位置:首頁   >>   資料下載   >>   1M001 Human MMP-13

1M001 Human MMP-13

時間:2013/10/11閱讀:360
分享:
  • 提供商

    上海逸峰生物科技有限公司
  • 資料大小

    419.5KB
  • 資料圖片

  • 下載次數(shù)

    44次
  • 資料類型

    WORD 文檔
  • 瀏覽次數(shù)

    360次
點擊免費下載該資料

                  

              

ELISA                                  

 

Human MMP-13

Catalogue Number 1M001

 

 

 

For the quantitative determination of Human Matrix metalloproteinase 13 concentrations in serum- body fluid - celiac fluid - tissue homogenate - culture fluid.

 

 

 

This package insert must be read in its entirety before using this product.

 

 

 

 

FOR RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.   

          http://www.rapidbio.org   

INTENDED USE AND TEST PRINCIPLE

This immunoassay kit allows for the quantitative determination of Human MMP-13 concentrations in serum, plasma, cell culture supernates and other biological fluids.

Add MMP-13 to pre-coated MMP-13 monoclonal antibody microelisa well, incubation; washing. Add HRP tagged MMP-13 antibodies. After another incubation and washing, remove the unbound enzyme, add Chromogen Solution A and B, the color of the liquid change into blue, and the color finally become yellow at the effect of acid. The depth of the color is positively correlated with concentration of the Porcine MMP-13 in samples.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1. 37 ℃ incubator

2. Standard microplate reader capable of measuring absorbance at 450 nm

3. Precision pipettes, disposable pipette tips and Absorbent paper

4. Distilled or deionized water

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 20 minutes at approximay 1000×g. Remove serum and assay immediay or aliquot and store samples at -20℃ or -80℃.Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

REAGENTS PROVIDED

Reagent

 

Storage

MICROTITER PLATE

96 wells

2-8℃

STANDARD.I

 0 pg/mL   1 ml

2-8℃ (-20℃)

STANDARD.II

50 pg/mL   1 ml

2-8℃ (-20℃)

STANDARD.III

100 pg/mL   1 ml

2-8℃ (-20℃)

STANDARD.IV

250 pg/mL  1 ml

2-8℃ (-20℃)

STANDARD.V

500 pg/mL  1 ml

2-8℃ (-20℃)

STANDARD.VI

1000 pg/mL  1 ml

2-8℃ (-20℃)

BIOLOGICAL

1.0 ml  1 vial

2-8℃ (-20℃)

 ENZYME CONJUGATE

10 ml  1 vial

2-8℃

SUBSTRATE A

6.0 ml  1 vial

2-8℃

SUBSTRATE B

6.0 ml  1 vial

2-8℃

STOP SOLUTION

6.0 ml  1 vial

2-8℃

WASH SOLUTION x100

10 ml  1 vial

2-8℃

Closure plate membrane

2 strips

-

 

PRECAUTIONS

  1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
  2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
  3. Do not use kit components beyond their expiration date.
  4. Use only deionized or distilled water to dilute reagents.
  5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
  6. Use fresh disposable pipette tips for each transfer to avoid contamination.
  7. Do not mix acid and sodium hypochlorite solutions.
  8. Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Human blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
  9. All samples should be disposed of in a manner that will inactivate viruses.
  10. Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
  11. Substrate Solution is easily contaminated. If bluish prior to use, do not use.
  12. Substrate B contaFE 20% acetone, keep this reagent away from sources of heat or flame.
  13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

ASSAY PROCEDURE

  1. Prepare all Standards before starting assay procedure (see Preparation Reagents). It is recommended that all Standards and Samples be added in duplicate to the Microtiter Plate.
  2. First, secure the desired number of coated wells in the holder, then add 50 μL of Standards or Samples to the appropriate well of the antibody pre-coated Microtiter Plate.
  3. Add 10 μL of Biological to samples well.(DO not add Biological to standards well).
  4. Add 100 μL of Enzyme Conjugate to each well. Mix well. Complete mixing in this step is important. Cover and incubate for 1 hour at 37°C.
  5. Prepare Substrate Solution no more than 15 minutes before end of incubation (see Preparation of Reagents).
  6. Wash the Microtiter Plate using one of the specified methods indicated below:
  7. Manual Washing: Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with distilled or de-ionized water, then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure four more times for a total of FIVE washes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly hen washing the plate to assure that all strips remain securely in frame.
  8. Automated Washing: Aspirate all wells, then wash plate FIVE times using distilled or de-ionized water. Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350 μL/well/wash (range: 350-400 μL). After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. It is recommended that the washer be set for a soaking time of 10 seconds or shaking time of 5 seconds between washes.
  9. Add 50 μL Substrate A&B to each well. Cover and incubate for 15 minutes at 20-25°C.
  10. Add 50 μL of Stop Solution to each well. Mix well.
  11. Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 30 minutes.

 

 

CALCULATION OF RESULTS

  1. This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis.
  2. First, calculate the mean O.D. value for each standard and sample. All O.D. values, are subtracted by the mean value of the zero standard before result interpretation. Construct the standard curve using graph paper or statistical software.
  3. To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.
  4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.
  5. The sensitivity by this assay is 1.0 pg/mL.
  6. Standard curve

 

 

 

上海逸晗生物科技有限公司代理不同品牌價格檔次的ELISA試劑盒。抗體產(chǎn)品等, 品種多,質(zhì)量好,價格實惠,并且還提供免費代檢測服務。
本公司的更多產(chǎn)品,請點擊公司:http://www.yihanbio.com/

 

 

 

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關企業(yè)負責,環(huán)保在線對此不承擔任何保證責任。

溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。

在線留言
美女麻豆颜色光屁股眼子| 色综合色狠狠天天综合色| 日韩欧美人妻综合| 久久精品国产亚洲av伦理| 日韩乱码一区二区三区中文字幕| 在线观看免费视频a v| 美女主播被操流水| 欧美精品第一区二区三区| 亚洲欧美日韩清纯唯美第一区| 色婷婷五月综合久久| 久久无码免费视频| 日本中文字幕无人区一区二区| 大粗鳮巴r教师人妻91| 国产午夜福利片无码视频| 最新中文字幕av不卡高清| 青青视频在线人视频在线| 黄色免费老人操逼| 久久久一区二区三区日本| 操女人大逼视频下载| 亚洲乱熟女一区二区三区| 午夜性福福利视频一区二区三区| 国产日韩精品v一区二区| 日韩欧美综合一二三区| 制服丝袜国产在线第一页| 91在线一区二区| 男插女逼啪啪啪软件| 想被操在线啊啊啊啊| 欧美日韩一区精品一区精品| 中文字幕乱码一区二区三区麻豆| 男人添女人下面免費视頻| 枫花恋精品一区二区久久| 黄片大鸡吧操小逼| 无码人妻免费一区二区三区| 亚洲大尺度无码无码专线一区| 国产欧美日韩一区二区在线观看| 一级e片在线观看| 精品国产自在现线看| 精品无码一区二区三区无码| 一区二区三区中文欧美| 亚洲精品自拍偷拍| 麻豆视频一级片在线观看|