【資料簡介】

 

 Human Interleukin 6 (IL-6) ELISA Kit
Catalog No. CSB-E04638h
(96T)
?          This immunoassay kit allows for the in vitro quantitative determination of human IL-6 concentrations in serum, plasma and cell culture supernates.
?          Expiration date six months from the date of manufacture
?          FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物經(jīng)營ELISA試劑盒及抗體、細胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價格實惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:  : /download(原版說明書下載)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to IL-6. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for IL-6 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain IL-6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ±2 nm. The concentration of IL-6 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
3.2 pg/ml-200 pg/ml. The standard curve concentrations used for the ELISA’s were 200 pg/ml, 100 pg/ml, 50 pg/ml, 25 pg/ml, 12.5 pg/ml, 6.2 pg/ml, 3.2 pg/ml.
SPECIFICITY
This assay recognizes human IL-6. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human IL-6 is typically less than 0.8 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1 Standard 2 Sample Diluent 1 x 20 ml Biotin-antibody Diluent 1 x 10 ml HRP-avidin Diluent 1 x 10 ml Biotin-antibody 1 x 120μl HRP-avidin 1 x 120μl
1 x 20 ml
Wash Buffer
(25×concentrate)
TMB Substrate 1 x 10 ml
Stop Solution 1 x 10 ml
STORAGE
1          Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2          Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3          A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1          Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2          Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 200 pg/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (200 pg/ml). The Sample Diluent serves as the zero standard (0 pg/ml). Prepare fresh for each assay. Use within 4 hours and discard after use.
3          Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
4          HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
?          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
?          Pipettes and pipette tips.
?          Deionized or distilled water.
?          Squirt bottle, manifold dispenser, or automated microplate washer.
?          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION AND STORAGE
?          Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
?          Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
?          Cell Culture Supernates Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1          Add 100μl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
2          Remove the liquid of each well, don’t wash.
3          Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.
4          Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200μl) and let it stand for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
5          Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
6          Repeat the aspiration and wash five times as step 4.
7          Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
8          Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
9          Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the IL-6 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
?          The kit should not be used beyond the expiration date on the kit label.
?          Do not mix or substitute reagents with those from other lots or sources.
?          It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed.
?          If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay.
?          Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
?          This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
?          Centrifuge vials before opening to collect contents.
?          When mixing or reconstituting protein solutions, always avoid foaming.
?          To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
?          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
?          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
?          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
?          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

廈門慧嘉生物科技有限公司作者

上一篇:同白斑綜合癥病毒PCR檢測試劑盒技術(shù)參數(shù)

下一篇:哈維氏弧菌PCR檢測試劑盒說明書


我要投稿
  • 投稿請發(fā)送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
  • 聯(lián)系電話0571-87759680
環(huán)保行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺
環(huán)保在線APP

功能豐富 實時交流

環(huán)保在線小程序

訂閱獲取更多服務(wù)

微信公眾號

關(guān)注我們

抖音

環(huán)保在線網(wǎng)

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環(huán)保在線

公眾號:環(huán)保在線

打開微信掃碼關(guān)注視頻號

快手

環(huán)保在線

快手ID:2537047074

打開快手 掃一掃關(guān)注
意見反饋
白虎鲍鱼抠逼免费看| 一级美女插逼百度| 午夜精品在线视频| 国产女做a爱全免费视频| 精品久久久久久久人妻换| 男插女逼啪啪啪软件| 天天躁久久躁中文字字幕| 999精品免费视频| 亚洲一区二区三区大胆视频| 色老头av亚洲三区三区| 澳门一区二区免费下线观看| 国产精品欧美久久久久久| 最新黄色A级一短片| 国产蜜月精品高清一区二区三区| 国产女明星一级毛片| 色男人天堂亚洲男人天堂| 一区二中文字幕在线看国产一区| 黑人大屌爆操骚货| 美女麻豆颜色光屁股眼子| 欧美大鸡巴操穴日韩| 啊啊不要你那痛死爽死了直播一区| 99国产精品一区二区| 亚洲国产精品一区亚洲国产| 藏经阁91福利私人试看| 国产青青操骚货在线观看| 亚洲av熟妇高潮精品啪啪| 看小伙草白女人比的黄片| 久久久久久国产A免费观看| 精品久久久久五月婷五月| 大粗鳮巴r教师人妻91| 欧美日韩一区精品一区精品| 亚洲精品自拍偷拍第一页| 欧美久久精品免费看C片| 中文字幕av一区二区三区蜜桃| 欧美男女舔逼舔鸡巴视频| 亚洲女同一区二区三久久精品| 在线12萝自慰喷水| 几巴怪物操逼视频| 三级片在线无码播放| 国产一区曰韩二区欧美三区| 亚洲欧美国产原创一区二区三区|